PPG CR vs. Fidelity

This page summarizes how compression ratio (CR) trades off against signal- and physiology-level fidelity for the v1 RVQ goldens. The Effective CR column is populated when an entropy-prior run is available; otherwise, the codec CR is the release-facing operating point. CRs are reported alongside the noise-aware metrics so it is easy to inspect the difference between waveform faithfulness, clean-reference fidelity, and physiological metric preservation.

Data source: measurements preserved from the original documentation.

CRCodec CREffective CRbits/tokNFaithful PRD%
02x2.00——97882.59
04x4.00——97893.44
08x8.00——97895.10
16x16.00——97897.54
32x32.00——633612.08
CRTruth PRD% (clean)PRDN-noise%HR MAE (bpm)Pulse-band PSD errCoherence
02x0.620.150.190.01550.9928
04x1.140.230.290.58850.9861
08x2.660.640.490.66230.9565
16x5.750.790.8812.56760.8991
32x12.350.201.790.03560.8014
CRSeam ratio
02x—
04x—
08x—
16x—
32x—

Noise-stratified detail (clean / median / noisy tertiles)

Section titled “Noise-stratified detail (clean / median / noisy tertiles)”

Tertiles are formed from a band-power noise estimate over each input recording; clean is the lowest-noise third, noisy is the highest.

CRTertileNPRD%PRDN-noise%HR MAE
02xclean32634.980.460.22
02xmedian32621.370.000.14
02xnoisy32631.420.000.22
04xclean32636.340.690.33
04xmedian32631.990.000.24
04xnoisy32631.980.000.30
08xclean32638.601.920.52
08xmedian32633.180.000.47
08xnoisy32633.510.000.49
16xclean326310.362.320.75
16xmedian32635.770.010.86
16xnoisy32636.490.041.04
32xclean211211.170.591.54
32xmedian211212.160.011.72
32xnoisy211212.900.002.11
CRTertilePulse-band PSD errCoherence
02xclean—0.9862
02xmedian—0.9963
02xnoisy—0.9959
04xclean—0.9784
04xmedian—0.9906
04xnoisy—0.9894
08xclean—0.9449
08xmedian—0.9655
08xnoisy—0.9592
16xclean—0.8928
16xmedian—0.9123
16xnoisy—0.8922
32xclean—0.8367
32xmedian—0.8015
32xnoisy—0.7660
  • Faithful PRD compares reconstruction with the recorded input; Truth PRD uses the fixture’s clean reference. Their difference depends on the input noise and reference construction.
  • PRDN-noise is a noise-normalized error measure. Interpret it with waveform and physiological errors, not as proof of denoising by itself.
  • HR MAE and band error describe the measurements in this evaluation. Acceptance thresholds depend on your application.
  • Seam ratio reports boundary energy relative to the window center. A missing value means no result was reported.
  • Sample counts and noise-bucket composition can differ across ratios. Preserve that context when comparing candidates.

See the validation scorecard for definitions and customer evidence for a compact comparison.