Skip to content
heliaEstimator
User guide
HELIA HUB

Interpret estimates

helx combines compiler output, simulator counters and platform parameters. These are different kinds of evidence. Preserve their provenance when reporting a result.

Output What it tells you
Compiler analysis The compiled model and its compiler-reported resource requirements
FVP counters Execution in the configured simulator environment
Energy estimate A calculation using counters and the platform energy model
Platform provenance The revision and confidence status of underlying values

Energy outputs depend on calibration and should be treated as experimental unless your evaluation explicitly establishes otherwise. Do not present estimates as measured silicon results.

  • Confirmed: values reviewed or measured by their owners.
  • Fitted: values tuned to reproduce reference measurements.
  • Unverified: specification values, estimates or placeholders without that confirmation.

The bundle records the least trusted status it depends on in provenance.values.status. A confirmed parameter does not turn a simulated experiment into a physical measurement.

Keep the model, compiler/runtime, platform revision, clock and memory configuration explicit. Change one variable at a time. Cross-check estimates against measurements on the intended hardware before using them for a product decision.